Skip to main content

Rib plating of acute and sub-acute non-union rib fractures in an adult with cystic fibrosis: a case report

Abstract

Background

Rib fractures associated with osteoporosis have been reported to occur ten times more frequently in adults with cystic fibrosis. Fractures cause chest pain, and interfere with cough and sputum clearance leading to worsened lung function and acute exacerbations which are the two main contributors to early mortality in cystic fibrosis. Usual treatment involves analgesics and time for healing; however considerable pain and disability result due to constant re-injury from chronic repetitive cough. Recently, surgical plating of rib fractures has become commonplace in treating acute, traumatic chest injuries. We describe here successful surgical plating in a White cystic fibrosis patient with multiple, non-traumatic rib fractures.

Case presentation

A-37-year old White male with cystic fibrosis was readmitted to Intermountain Medical Center for a pulmonary exacerbation. He had developed localized rib pain while coughing 2 months earlier, with worsening just prior to hospital admission in conjunction with a “pop” in the same location while bending over. A chest computerized tomography scan at admission demonstrated an acute 5th rib fracture and chronic non-united 6th and 7th right rib fractures. An epidural catheter was placed both for analgesia and to make secretion clearance possible in preparation for the surgery performed 2 days later. Under general anesthesia, he had open reduction and internal fixation of the right 5th, 6th and 7th rib fractures with a Synthes Matrix rib set. After several days of increased oxygen requirements, fever, fluid retention, and borderline vital signs, he stabilized. Numerical pain rating scores from his ribs were lower post-operatively and he was able to tolerate chest physical therapy and vigorous coughing.

Conclusions

In our case report, rib plating with bone grafting improved rib pain and allowed healing of the fractures and recovery, although the immediate post-op period required close attention and care. We believe repair may be of benefit in selected cystic fibrosis patients, such as our patient who had suffered multiple rib fractures that were healing poorly.

Background

Rib fractures associated with osteoporosis have been reported to occur ten times more frequently in adults with cystic fibrosis (CF) [1]. Fractures cause chest pain, and interfere with cough and sputum clearance leading to worsened lung function and acute exacerbations which are the two main contributors to early mortality in CF [2]. Usual treatment involves analgesics and time for healing; however considerable pain and disability result due to constant re-injury from chronic repetitive cough. Recently, surgical plating of rib fractures has become commonplace in treating acute, traumatic chest injuries [3]. Reported advantages include control of pain, and more rapid and complete healing of rib fractures [4]. In patients with CF, pain control may restore the ability to resume airway clearance, a critical element of maintenance therapy. In these patients, rib repair may be more effective than oral medications for controlling episodic but short-lived intense pain. We describe here successful surgical plating in a CF patient with multiple, non-traumatic rib fractures.

Case presentation

A 37-year-old White male with CF identified at 3½ months, mutations F508del and R560T, was readmitted to Intermountain Medical Center for a pulmonary exacerbation. One week following discharge from his previous hospitalization 3 months earlier, he coughed hard and developed immediate focal pain in his right chest, mid to anterior axillary line at the 6th and 7th thoracic levels. He was seen in the emergency department and chest x-rays showed no abnormalities. He was treated symptomatically with oral analgesics; the pain waxed and waned but never resolved. A month later he had a particularly vigorous cough, and he felt a pop in the same area with even more pain. The pain worsened further just prior to readmission when his chest “popped” again while tying his shoe. A chest computerized tomography scan at admission (Figure 1) demonstrated an acute 5th rib fracture and chronic non-united 6th and 7th right rib fractures. He was taking chronic Vitamin D and calcium supplements and had a 25 hydroxyvitamin D2 and D3 level in the normal range (33 nanograms per milliliter). Forced expiratory volume in 1 second on admission was 0.66 liter (19% of predicted), and forced vital capacity 2.59 liters (61% of predicted), decreased from 0.80 (23% of predicted) and 2.73 (64% of predicted) at the end of his prior admission. His lungs are chronically infected with mucoid Pseudomonas aeruginosa. His body mass index at admission was 23; he had taken only a few short courses of corticosteroids over his lifetime.

Figure 1
figure 1

Chest computerized tomography rib reconstruction shows 2 non-union subacute fractures, and the acute fracture in the adjacent 5th rib.

Because of three contiguous fractures and the need for aggressive sputum clearance to treat his exacerbation, operative repair was recommended. An epidural catheter was placed both for analgesia and to make secretion clearance possible in preparation for the surgery performed 2 days later.

Under general anesthesia, he had open reduction and internal fixation of the right 5th, 6th and 7th rib fractures with a Synthes Matrix rib set (Figure 2) [5]. The fracture sites were buttressed with iliac crest bone grafts. No chest tube placed, because the lung was attached to the parietal pleura likely from a prior, iatrogenic pneumothorax 13 years earlier that had required a chest tube. He was extubated in the recovery room and returned to a ward bed. After several days of increased oxygen requirements, fever, fluid retention, and borderline vital signs, he stabilized. Numerical pain rating scores are illustrated in Table 1[6]. The fixated ribs were less painful to him post-operatively than the iliac crest bone harvest site. Bioavailable testosterone was low at 45.9 milligrams per deciliter (normal range 131–682), and replacement therapy was initiated. At discharge, lung function had plateaued with forced expiratory volume in 1 second 0.71 liter (21% of predicted) and forced vital capacity 2.26 liters (53% of predicted), but he was subjectively improved.

Figure 2
figure 2

Operating room photograph of plates bridging two of the rib fractures.

Table 1 Numeric pain rating scale scores at 4 different time intervals during hospitalization, rated 0 to 10 with 10 being severe pain

He gradually recovered from the surgery as an outpatient and resumed full time employment. He was readmitted 3 times over the subsequent year for acute pulmonary exacerbations, similar to his prior disease pattern. At the time of discharge one year post surgery, forced expiratory volume in 1 second was 0.89 liter (26% of predicted), and forced vital capacity 2.97 liters (79% of predicted), improved even compared with measurements over the year prior to the rib fractures. He has no pain or deformity in his right chest.

Conclusions

Rib fractures are a common and significant cause of pain and morbidity in CF patients [1]. Rib fracture pain is difficult to treat with analgesics such as non-steroidal anti-inflammatory drugs and opiates because of the episodic and intense nature of cough. Rib pain impairs sputum clearance and leads to exacerbations of CF pulmonary disease, which may be the single most important factor leading to worsening lung function and prognosis. Poor healing and non-union of fractures may be more common in this patient group because of poor nutrition, low testosterone and vitamin D, and daily hard coughing.

In our case report, rib plating with bone grafting improved rib pain and allowed healing of the fractures and recovery, although the immediate post-op period required close attention and care. Surgical repair of fractures has been utilized primarily in trauma patients, particularly those with flail chests and respiratory failure. We believe repair may be of benefit in selected CF patients, such as our patient who had suffered multiple rib fractures that were healing poorly. Absent this surgery, we believe that his severe pulmonary exacerbation at the time of hospitalization would have been very difficult to treat successfully. Follow up at 1 year documented excellent functional outcome.

In the future, our patient might be considered for lung transplantation. Lung transplants are performed via median sternotomy, with access to the chest as well between the 5th and 6th interspace. Discussion with Utah lung transplant surgeons suggest that the presence of rib plates would not preclude the option of future lung transplantation, although fractures might occur at both ends of the titanium plates.

We recommend a randomized trial or at least case series of rib plating to treat multiple rib fractures in CF patients, and an attempt to determine whether bone grafting as an adjunct to the Matrix device is necessary.

Consent

Written informed consent was obtained from the patient for publication of this Case Report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Abbreviations

CF:

Cystic fibrosis

References

  1. Aris RM, Renner JB, Winders AD, Bucli HE, Riggs DB, Lester GE, David A, Ontjes DA: Increased rate of fractures and severe kyphosis: sequelae of living into adulthood with cystic fibrosis. Ann Intern Med. 1998, 128: 186-193. 10.7326/0003-4819-128-3-199802010-00004.

    Article  PubMed  CAS  Google Scholar 

  2. Liou TG, Adler FR, Fitzsimmons SC, Cahill BC, Hibbs JR, Marshall BC: Predictive 5-year survivorship model of cystic fibrosis. Am J Epidemiol. 2001, 153: 345-52. 10.1093/aje/153.4.345.

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  3. Bottlang M, Long WB, Phelan D, Fielder D, Madey SM: Surgical stabilization of flail chest injuries with MatrixRIB implants: a prospective observational study. Injury. 2013, 44 (2): 232-8. 10.1016/j.injury.2012.08.011.

    Article  PubMed  Google Scholar 

  4. Billè A, Okiror L, Campbell A, Simons J, Routledge T: Evaluation of long-term results and quality of life in patients who underwent rib fixation with titanium devices after trauma. Gen Thorac Cardiovasc Surg. 2013, 61 (6): 345-9. 10.1007/s11748-013-0218-4.

    Article  PubMed  Google Scholar 

  5. Matrix rib, DePuy Synthes, Johnson and Johnson North America. [http://sites.synthes.com/na/matrixrib/]

  6. McCaffery M, Pasero C: Pain: Clinical Manual. 1999, St. Louis: Mosby, Inc, P. 16

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nathan C Dean.

Additional information

Competing interests

The authors declare that they have no competing interests; this work was not supported by external funding.

Authors’ contributions

ND led the conception and design, acquisition of data, and analysis and interpretation of data. DVB led the surgical team and provided the figures. All 3 authors drafted the manuscript or revised it critically for important intellectual content; have given final approval of the version to be published; and agree to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Authors’ original file for figure 2

Authors’ original file for figure 3

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dean, N.C., Van Boerum, D.H. & Liou, T.G. Rib plating of acute and sub-acute non-union rib fractures in an adult with cystic fibrosis: a case report. BMC Res Notes 7, 681 (2014). https://0-doi-org.brum.beds.ac.uk/10.1186/1756-0500-7-681

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/1756-0500-7-681

Keywords